Fireboy Xintex CMD6-MB-B CO Detector - Alarm Internal Battery Black - CMD6-MB-BR
Protect enclosed boat cabins and sleeping berths without running 12V/24V wiring or draining house batteries using the Fireboy Xintex CMD6-MB-B CO Detector. ETL-tested to UL 2034 Marine (4th Edition) and ABYC A-24 compliant, this black-housing detector pairs a 7-year sealed lithium-metal battery with Time-Weighted Average (TWA) electrochemical sensing.
By buying this product you can collect up to 18 Citimarine points. Your cart will total 18 points that will be converted into a voucher of $1.80 towards your next purchase! Must be logged in to collect points.
Fireboy Xintex CO Detector - Wire-Free Marine Carbon Monoxide Protection with Fireboy-Xintex CMD6-MB - CMD6-MB-BR
Introducing the Fireboy-Xintex CMD6-MB-B Marine Carbon Monoxide Alarm (Ref: CMD6-MB-BR; also available in White as CMD6-MB-R), a wire-free, battery-operated CO detector purpose-built to safeguard enclosed yacht salons, staterooms, and cabin berths against colorless, odorless exhaust fumes. Powered entirely by a permanent, factory-sealed internal lithium-metal battery rated for an approximate 7-year (84-month) service life, the CMD6-MB eliminates 12V/24V DC power wiring, panel circuit breakers, and parasitic house-battery draw during seasonal layup or extended mooring.
Time-Weighted Average (TWA) Sensing & Nuisance-Alarm Reduction
Marine environments frequently experience brief exhaust gusts during tight marina docking or backing down. Rather than triggering false alarms from momentary spikes, the microprocessor-controlled electrochemical sensor continuously tracks carbon monoxide concentration, ambient temperature, and exposure duration using a Time-Weighted Average (TWA) calculation. Programmed to sound an 85 dB (@ 3.05 m / 10 ft) audible horn and flash a red status LED when blood carboxyhemoglobin (COHb) reaches a 10% threshold, the unit alarms within 60–240 minutes at 70 ppm, 10–50 minutes at 150 ppm, and 4–15 minutes at 400 ppm, automatically resetting once CO drops below 40 ppm.
Marine-Grade Durability, Self-Diagnostics & ABYC Placement
ETL-tested to UL Standard 2034 Marine (4th Edition) and compliant with ABYC A-24 guidelines, the CMD6-MB features a moisture- and corrosion-sealed conformal-coated circuit board housed in a compact 3.5 in x 3.5 in x 1.25 in flame-retardant Polylac PA-765 (ABS-FR) enclosure. Every 180 seconds, internal self-diagnostics check critical sensor circuitry and flash a green status LED to confirm normal operation. Per ABYC A-24.7.2, one alarm should be mounted at eye level (or on the ceiling) in the main cabin and in every partitioned sleeping area—at least 5 ft (1.5 m) away from cooking appliances or direct HVAC vents and 1 ft (0.3 m) clear of corners or dead-air spaces.
Fast Surface Installation & Two-Step Initial Activation
The twist-lock mounting base installs vertically on any cabin bulkhead using two #6 pan-head screws—requiring zero wire holes for standalone battery models—and shares the exact footprint of Fireboy CMD5-M alarms (an optional CMD6 Conversion Plate 100102-B/W covers larger cutouts left by legacy CMD2-M, CMD3-M, or CMD4-M detectors). Before activating, remove the temporary protective installation cover, lock the alarm clockwise 25° onto its mounting plate, hold the Test/Mute button for 10 seconds until the green LED illuminates, and press Test/Mute 5 times until both LEDs flash and the horn sounds.
- 100% Wire-Free Internal Battery Power: Sealed maintenance-free lithium-metal battery powers the alarm for its full ~7-year (84-month) sensor life with zero drain on vessel 12V/24V banks.
- UL 2034 Marine & ABYC A-24 Tested: Vibration-, shock-, and humidity-resistant conformal-coated PCB built specifically for gasoline, diesel, generator, and propane-equipped vessels.
- Microprocessor TWA Electrochemical Sensor: Calculates 10% COHb accumulation over time to prevent nuisance alarms during brief docking maneuvers while reacting rapidly to high CO concentrations.
- 180-Second Automated Self-Check: Continuously verifies critical components and provides distinct LED and 85 dB horn patterns for Normal, Alarm, Fault, and 7-Year End-of-Life states.
- Compact Low-Profile Footprint: Measures just 3.5" x 3.5" x 1.25" (89 x 89 x 32 mm) in stealthy Black (CMD6-MB-BR) or classic White (CMD6-MB-R) to blend cleanly into modern yacht interiors.
- Primary Marine Applications: Aft cabins, V-berths,enclosed pilothouses, convertible yacht salons, cuddy cabins, and auxiliary-generator vessels susceptible to the "station wagon effect."

Configuration Options - Standalone Internal Battery Series
| Housing Color | CitimarineStore Reference (Retail) | OEM Base Model | UPC / GTIN | Power Source | Interconnect / Relay |
|---|---|---|---|---|---|
| Black Housing | CMD6-MB-BR | CMD6-MB-B | 619749208563 | Sealed Internal Lithium-Metal Battery | No (Standalone) |
| White Housing | CMD6-MB-R | CMD6-MB | 619749208662 | Sealed Internal Lithium-Metal Battery | No (Standalone) |
Technical Specifications - Fireboy Xintex CMD6-MB-B (Ref: CMD6-MB-BR)
| Attribute | Verified Specification |
|---|---|
| Brand / Manufacturer | Fireboy-Xintex |
| Model / OEM Part Number | CMD6-MB-B (Black) / CMD6-MB (White) — Manual P/N 18160 Rev H |
| UPC / Barcode | 619749208563 (Black CMD6-MB-BR) / 619749208662 (White CMD6-MB-R) |
| Product Type | Standalone Battery-Powered Marine Carbon Monoxide (CO) Alarm |
| Sensor Technology | Microprocessor-Controlled Electrochemical CO Sensor |
| Power Source | Permanent, Non-Removable Sealed Lithium-Metal Battery (No external wiring) |
| Vessel 12V / 24V Current Draw | None (0 mA external draw) |
| Approximate Sensor & Battery End-of-Life (EOL) | Approximately 84 months (7 years) from activation / retail sale |
| Alarm Method & Threshold | Time-Weighted Average (TWA) programmed to 10% COHb |
| CO Response Times | 70 ppm: 60–240 min | 150 ppm: 10–50 min | 400 ppm: 4–15 min | Reset: < 40 ppm |
| Audible Alarm Horn | 85 dB @ 3.05 m (10 ft) — 4 beeps followed by 5 seconds silence |
| Visual Status Indicators | Green LED (1 flash / 180 sec normal) & Red LED (1 flash / 5 sec alarm or EOL) |
| Self-Diagnostic Interval | Every 180 seconds (3 minutes) |
| Interconnect & Generator Shutdown Relay | Not included on CMD6-MB series (requires CMD6-MBR-BR or CMD6-MDR-BR models) |
| Operating & Storage Temperature | -40°F to 158°F (-40°C to 70°C) |
| Housing Material | Polylac PA-765 (Flame-Retardant ABS-FR) with conformal-coated PCB |
| Dimensions (L x W x D) | 3.5" x 3.5" x 1.25" (89 mm x 89 mm x 32 mm) |
| Safety Standards & Certifications | ETL Tested to UL STD 2034 Marine (4th Edition); Meets ABYC A-24 |
| Manufacturer Warranty | 1-Year Limited Manufacturer Warranty |
What's in the Box
- 1 x Fireboy-Xintex CMD6-MB-B Black Marine Carbon Monoxide Alarm with Sealed 7-Year Lithium Battery (Ref: CMD6-MB-BR)
- 1 x Twist-Lock Surface Mounting Base Plate
- 1 x Temporary Protective Installation Cover (remove prior to activation)
- 2 x CO Safety & Replacement-Date Warning Stickers
- 1 x Owner's Manual & Installation Instructions (P/N 18160)
- Sold Separately for Installation: Two #6 pan-head mounting screws (length matched to bulkhead thickness) and optional Fireboy CMD6 Conversion Plate (100102-B Black or 100102-W White) when retrofitting over larger CMD2-M, CMD3-M, or CMD4-M cutouts.
Frequently Asked Questions - Fireboy-Xintex CMD6-MB-B (CMD6-MB-BR)
Can the internal battery in the Fireboy-Xintex CMD6-MB-BR be replaced?
No, the lithium-metal battery inside this unit is permanently sealed and non-removable, and attempting to remove it will void the manufacturer warranty. The sealed battery is engineered to power the detector for the full approximate 84-month (7-year) service life of the electrochemical CO sensor, after which the entire unit is deactivated and replaced.
What is the difference between CMD6-MB-BR, CMD6-MBR-BR, and CMD6-MD-BR?
CMD6-MB-BR is a standalone, wire-free internal battery CO alarm in a black housing with no external wiring. CMD6-MBR-BR is battery-powered but adds 18 AWG wiring leads to interconnect up to 10 alarms and trigger a 1A/32V DC generator shutdown relay. CMD6-MD-BR hardwires directly into your boat's 12V or 24V DC electrical system.
How do I activate and weekly-test the CMD6-MB-BR marine CO alarm?
First remove the protective installation cover, then press and hold the Test/Mute button for 10 seconds until the green LED illuminates, followed immediately by pressing Test/Mute 5 times until both LEDs flash and the horn sounds. For weekly testing, hold Test/Mute until the green LED turns on and release to trigger two simulated 4-beep alarm cycles.
Will the CMD6-MB-BR fit the mounting holes from an older Fireboy CMD-series detector?
The CMD6-MB-BR uses the exact same compact 3.5-inch square housing footprint and twist-lock bracket geometry as the Fireboy CMD5-M series. If you are replacing an older, larger Fireboy CMD2-M, CMD3-M, or CMD4-M unit, order the optional black CMD6 Conversion Plate (Part # 100102-B) to cover legacy screw holes and bulkhead wear.
Why is my Fireboy CMD6 alarm chirping once every 60 seconds with a flashing red LED?
A single audible beep every 60 seconds paired with one red LED flash every 5 seconds (and the green LED off) indicates the alarm has reached its 84-month (7-year) End-of-Life (EOL). Remove the unit, permanently deactivate it via the internal uni-directional screw per the manual, and install a new marine CO detector.
Does this detector sense smoke, gasoline fumes, or propane gas, and where should it be mounted?
No, the CMD6-MB-BR detects carbon monoxide (CO) from combustion sources only and will not detect smoke, fire, gasoline vapors, or propane leaks. Per ABYC A-24.7.2, install one detector at eye level or on the ceiling in the main cabin and in each sleeping area, keeping at least 5 feet from cooking stoves or vents and 1 foot from corners.