EasyStart™ 366 requires that you wire in your own compressor start capacitor. The values required are described in the table below. Micro-Air does not stock all of the values listed in this table. Part Number: CAP-125 Order Processing time will be 7-10 Days
Compressor Triac Replacement Relay. When used with a high-current triac that controls the compressor switching, EasyStart requires that the triac be replaced with a power relay. This replacement relay is designed with mounting that matches the footprint of the Sanrex® TG35F40 triac, commonly used in marine air conditioners. Fully compatible with dometic and cruisair units. Part Number: ASY-503-X2D / 4120050
The 2-station Pump Relay (PRP) boards allow control of a common seawater pump between multiple cabins or chiller controls. It can also be used to control a common chilled-water loop pump between multiple chiller controls. Fully-isolated pump trigger inputs accept either 115V/60Hz or 230V/50Hz. The pump power source and pump output is also isolated and can be either 115V or 230V. Triggers not needed, integrated into the board. Part Number: ASY-110-X01
The 6-station Pump Relay (PRP) boards allows control of a common seawater pump between multiple cabin or chiller controls. It can also be used to control a common chilled-water loop pump between multiple chiller controls. Fully-isolated pump trigger inputs accept either 115V/60Hz or 230V/50Hz. The pump power source and pump output is also isolated and can be either 115V or 230V . Triggers not needed, integrated into the board. Part Number: ASY-111-X01
This Pump Relay board (PRP) (BOARD ONLY, NOT METAL BOX) allows control of a common seawater pump between multiple cabin or chiller controls. It can also be used to control a common chilled-water loop pump between multiple chiller controls. Separate, fully-isolated pump trigger inputs accept either 115VAC/60Hz or 230VAC/50-60Hz. The pump power source and pump output is also isolated and can be either 115VAC or 230VAC/50-60Hz. Triggers not needed, included in board. 6-Stations model in stock only.
The MA Replacement Trigger is a newly-manufactured, footprint-compatible, and functionally-compatible replacement trigger for use in the popular pump relay boxes for marine applications. The MA Replacement Trigger is dual-voltage and therefore you only need one part to work in both 115V and 230V applications. This trigger is used in the pump relay box. It is compatible with Dometic TR-115 and TR-230 Triggers. Part Number: ASY-599-X01 / TR 115 - TR 230
CTM retrofit kit to upgrade older mechanical controls to New SMXir or Digital Controls using U-Board. Cables, SMXir, Passport I/O or Digital Controls are sold separately. 90-day warranty*. Part Number: 40000J
NEW DOMETIC SmartStart III. SOFT STARTER FOR MARINE AIR CONDITIONING, 9A-32A Continuous. The Dometic Smart Start soft starter protects electronics by reducing start-up spikes in your boat's air conditioner. Avoid Voltage Spikes, avoid power outages, reduced startup amps. 90-day warranty*.
Please see all micro-air easy starts here
A-548, Replacement To-3 Triac. This triac triggers the pumps when the A/C unit needs them on. This Trac is located inside of the Pump relay Box. 90-day warranty*. Peak Voltage: 400V, Amperage: 35A. NOT IN STOCK, CONTACT US FOR ETA Part Number: 758000006 / TG35F 40
Marine air conditioner motor start relay / Motor Starting Relay. Dealer Design Award Winner. Replacement for all standard potential relays - 50A. Input: 110-270 VAC Single Phase. Maximum Voltage Contact: 502 VAC (absolute). Motor Power Rating: Up to 10 HP. 90-day warranty on this air conditioner relay*. Part Number: 290339860